Suhm Spring Works - Materials Properties
Material |
Material
Properties |
Maximum
Working Temp. |
|
Modulus
of Elasticity |
Approx.
Design % of Ultimate Tensile (torsional) |
Common
Sizes, mm |
AISI
316 Stainless Steel Wire ASTM A313 |
Cold drawn.
Better corrosion resistance than
302/304. Good for elevated
temperatures. No magnetism. |
285°C |
1689/758 |
(E)
193k |
40%
|
0,43
to 14,3 |
Wire Diameter, mm |
|||||||||
0,43 |
0,74 |
0,99 |
1.30 |
1.70 |
2,16 |
2,67 |
3,61 |
5,54 |
7,93 |
0,46 |
0,76 |
1,02 |
1.37 |
1.73 |
2,18 |
2,62 |
3,76 |
5,72 |
8,41 |
0,51 |
0,79 |
1,04 |
1.40 |
1.78 |
2,24 |
2,77 |
3,96 |
5,94 |
8,71 |
0,56 |
0,81 |
1,07 |
1.42 |
1.83 |
2,29 |
2,85 |
4,12 |
6,35 |
9,20 |
0,58 |
0,84 |
1,09 |
1.45 |
1.93 |
2,31 |
2,92 |
4,37 |
6,66 |
9,53 |
0,61 |
0,86 |
1,12 |
1.47 |
1.98 |
2,39 |
3,00 |
4,50 |
7,16 |
10,31 |
0,64 |
0,89 |
1,14 |
1.50 |
2.03 |
2,41 |
3,05 |
4,75 |
7,19 |
11,10 |
0,66 |
0,91 |
1,19 |
1.52 |
2.08 |
2,49 |
3,18 |
4,88 |
7,42 |
11,89 |
0,69 |
0,94 |
1,25 |
1.58 |
2.11 |
2,54 |
3,43 |
5,16 |
7,62 |
12,70 |
0,71 |
0,97 |
1,27 |
1.65 |
2.13 |
2,57 |
3,51 |
5,26 |
7,77 |
14,28 |
Diameter, mm |
Tensile Strength, MPa |
|
minimum |
maximum |
|
Up
to 0,25 incl. |
1690 |
1895 |
Over
0,25 to 0,38 incl. |
1655 |
1860 |
Over
0,38 to 0,61 incl. |
1620 |
1825 |
Over
0,61 to 1,04 incl. |
1620 |
1825 |
Over
1,04 to 1,19 incl. |
1585 |
1790 |
Over
1,19 to 1,37 incl. |
1550 |
1760 |
Over
1,37 to 1,57 incl. |
1515 |
1725 |
Over
1,57 to 1,83 incl. |
1480 |
1690 |
Over
1,82 to 2,03 incl. |
1450 |
1655 |
Over
2,03 to 2,34 incl. |
1415 |
1620 |
Over
2,34 to 2,67 incl. |
1380 |
1585 |
Over
2,67 to 3,05 incl. |
1345 |
1550 |
Over
3,05 to 3,76 incl. |
1275 |
1480 |
Over
3,76 to 4,22 incl. |
1240 |
1450 |
Over
4,22 to 4,50 incl. |
1170 |
1380 |
Over
4,50 to 5,26 incl. |
1105 |
1310 |
Over
5,26 to 5,72 incl. |
1070 |
1275 |
Over
5,72 to 6,35 incl. |
1035 |
1240 |
Over
6,35 to 7,92 incl. |
965 |
1170 |
Over
7,92 to 9,53 incl. |
930 |
1140 |
Over
9,53 to 12,70 incl. |
895 |
1105 |
Over
12,70 |
850 |
1970 |
A When wire is specified in straightened and cut lengths, the minimum tensile strength shall be 90% of the values listed in the table.
These data are provided as a reference guide only and are not intended for design purposes. Strength values and sizes are subject to change. Please check with a Suhm Spring representative for confirmation.